FESTO   VSNC-F-B52-D-G14-F8-1B2 Solenoid Valve

FESTO VSNC-F-B52-D-G14-F8-1B2 Solenoid Valve

You can get an offer for the FESTO VSNC-F-B52-D-G14-F8-1B2 Solenoid Valve product of the brand FESTO right now!

GET OFFER


FESTO VSNC-F-B52-D-G14-F8-1B2 Solenoid Valve Details

  • Product Name: FESTO VSNC-F-B52-D-G14-F8-1B2 Solenoid Valve
  • Brand: FESTO
  • Keywords: FESTO, , FESTO , , FESTO , , FESTO , VSNC-F-B52-D-G14-F8-1B2, FESTO VSNC-F-B52-D-G14-F8-1B2

If you have any questions, please mail to info@industrialpart.de.

Valve function 5/2, bistable 5/2 or 3/2 switchable 5/3, pressurized 5/3, exhausted 5/3, closed Actuation type Electrical Width 32 mm Standard nominal flow rate 800 l/min ... 1350 l/min Pneumatic working port NAMUR connection diagram Operating voltage 110V AC 120V AC 12V DC 230V AC 240V AC 24V AC 24V DC 48V AC 48V DC Via solenoid coil, to be ordered separately Operating pressure 0.15 MPa ... 1 MPa Operating pressure 1.5 bar ... 10 bar Structural design Piston gate valve Plate seat Reset method Mechanical spring Certification c UL us - Recognized (OL) CE marking (see declaration of conformity) as per EU explosion protection directive (ATEX) As per EU low voltage directive Explosion protection certification outside the EU Class I, Div. 1 (US) Class I, Div. 2 (US) Class II, Div. 1 (US) Class II, Div. 2 (US) Class III, Div. 1 (US) Class III, Div. 2 (US) EPL Da (IEC-EX) EPL Db (IEC-EX) EPL Db (KR) EPL Dc (KR) EPL Ga (IEC-EX) EPL Ga (KR) EPL Gb (IEC-EX) EPL Gb (KR) EPL Gc (KR) Certificate issuing authority DNVGL-TAA000011J ATEX category gas II 2G II 3G ATEX category for dust II 2D II 3D Type of ignition protection for gas AEx m II T4 Ex db IIC T4 Gb Ex db IIC T5 Gb Ex ia IIC T6 Ga Ex ia IIC T6...T5 Ga Ex mb IIC T6 Ex nA IIC T5 X Gc Type of (ignition) protection for dust Ex ia IIIB T135°C Da Ex mb tb IIIC T80°C Ex t IIIC T80°C Db Ex tb IIIC T100°C Db Ex tb IIIC T135°C Db Ex tc IIIC T95°C X Dc Explosive ambient temperature -20°C <= Ta <= +50°C -20°C <= Ta <= +60°C -40°C <= Ta <= +50°C -40°C <= Ta <= +65°C -65°C <= Ta <= +40°C -65°C <= Ta <= +55°C Degree of protection IP65 IP66 IP67 With plug socket as per IEC 60529 Exhaust air function With flow control option Sealing principle Soft Mounting position Any Conforms to standard VDI/VDE 3845 (NAMUR) Manual override Detenting None Non-detenting Covered Type of control Pilot-controlled Pilot air supply port Internal Flow direction Non-reversible Symbol 00991005 00991018 00991021 00991080 00991082 00991083 00991728 00991831 00991953 00995701 Lap Overlap Underlap Signal status display With accessories b-value 0.4 ... 0.5 C value 2.1 l/sbar ... 5.6 l/sbar Standard nominal flow rate, exhaust air return 4->3 110 l/min Switching time off 6 ms ... 120 ms On switching time 4 ms ... 35 ms Changeover time 2 ms ... 55 ms Duty cycle 100% Coil characteristics 110/120 V AC: 50/60 Hz, initial power 2.7 VA, holding power 1.9 VA 110/120 V AC: 50/60 Hz, initial power 4.4 VA, holding power 3.3 VA 110/120 V AC: 50/60 Hz, initial power 5.2 VA, holding power 3.1 VA 110/120 V AC: 50/60 Hz, initial power 6.9 VA, holding power 3.1 VA 110 V AC: 50/60 Hz, initial power 7.7 VA, holding power 3.8 VA 120 V AC: 60 Hz, initial power 10.0 VA, holding power 6.8 VA 12 V DC: 2.8 W 12 V DC: 3.4 W 230/240 V AC: 50/60 Hz, initial power 3.9 VA, holding power 2.8 VA 230/240 V AC: 50/60 Hz, initial power 5.8 VA, holding power 4.6 VA 230 V AC: 50/60 Hz, initial power 10.0 VA, holding power 6.0 VA 230 V AC: 50/60 Hz, initial power 11.5 VA, holding power 8.0 VA 230 V AC: 50/60 Hz, initial power 6.2 VA, holding power 3.7 VA 230 V AC: 50/60 Hz, initial power 6.9 VA, holding power 4.1 VA 24 V DC: 0.8 W 24 V DC: 2.1 W 24 V DC: 2.7 W 24 V DC: 3.3 W 24 V DC: 4.6 W 24 V AC: 50/60 Hz, initial power 2.5 VA, holding power 1.7 VA 24 V AC: 50/60 Hz, initial power 3.9 VA, holding power 2.6 VA 24 V DC: 0.7 W 24 V DC: 1.2 W 24 V DC: 2.6 W 48 V AC: 50/60 Hz, initial power 2.5 VA, holding power 1.7 VA 48 V AC: 50/60 Hz, initial power 3.9 VA, holding power 2.7 VA 48 V DC: 2.8 W 48 V DC: 3.4 W See solenoid coil, to be ordered separately Permissible voltage fluctuations +/- 10 % Explosion prevention and protection Class I, Div. 1 (US) Class I, Div. 2 (US) Class II, Div. 1 (US) Class II, Div. 2 (US) Class III, Div. 1 (US) Class III, Div. 2 (US) Observe the information on the certificate Zone 0 (IEC-EX) Zone 0 (KR) Zone 1 (ATEX) Zone 1 (IEC-EX) Zone 1 (KR) Zone 2 (ATEX) Zone 2 (KR) Zone 20 (IEC-EX) Zone 21 (ATEX) Zone 21 (IEC-EX) Zone 21 (KR) Zone 22 (ATEX) Zone 22 (KR) Operating medium Compressed air as per ISO 8573-1:2010 [7:4:4] Information on operating and pilot media Operation with oil lubrication possible (required for further use) Corrosion resistance class (CRC) 2 - Moderate corrosion stress LABS (PWIS) conformity VDMA24364-B2-L Temperature of medium -20 °C ... 60 °C Ambient temperature -20 °C ... 60 °C Product weight 335 g ... 685 g Electrical connection 3-pin Form A Form B Cable connector M20x1.5 M12x1, A-coded as per EN 61076-2-101 Plug as per EN 175301-803 As per industrial standard (11 mm) Type of mounting With through-hole Venting hole connection Not ducted Pneumatic connection 1 G1/4 1/4 NPT QS-6 QS-8 QS-10 QS-1/4 QS-5/16 QS-3/8 Pneumatic connection 2 NAMUR connection diagram Pneumatic connection 3 G1/4 1/4 NPT QS-6 QS-8 QS-10 QS-1/4 QS-5/16 QS-3/8 Pneumatic connection 4 NAMUR connection diagram Pneumatic connection 5 G1/4 1/4 NPT QS-6 QS-8 QS-10 QS-5/16 QS-1/4 QS-3/8 Note on materials RoHS-compliant Seals material NBR Housing material Wrought aluminum alloy Material of screws Steel, galvanized

About the FESTO

You can contact us for all products of the brand FESTO. We will send you a special offer as soon as possible!

 

Other Products FESTO




Looking an Industrial Part for your Company?

Contact us today for quote or more information.

Get In Touch